Mixed zone (homes with offices/shops) — ΠΕΡΙΟΧΗ ΜΕ ΕΠΙΚΡΑΤΟΥΣΑ ΧΡΗΣΗ ΤΗΝ ΚΑΤΟΙΚΙΑ ΚΑΙ ΓΡΑΦΕΙΑ Verified

Homes together with offices, shops or light business uses in the same building or area.

Development limits

Building ratio (Σ.Δ.)
1
Coverage (Σ.Κ.)
0.5
Floors
3
Height
13.5 m

Example: On a 1000 m² plot in zone ΚΓ5α you could build roughly 1000 m² of floor area with a footprint of up to 500 m². Boundary setbacks, road widening and the plan's conditions can reduce this — see the calculation for your own plot.

Limits per use

UseBuilding ratio (Σ.Δ.)Coverage (Σ.Κ.)FloorsHeight
Κ10.5313.5 m
Γ10.5313.5 m
Α.Ξ.10.5313.5 m

Source: DTPH Υπόμνημα Πολεοδομικών Ζωνών (data.gov.cy, 2016), row 115